Two oxygen flowmeters can carry the same flow range on the label and still require different fittings. For overseas buyers and distributors, that distinction can determine whether a sample fits the intended outlet or the order needs to be revised. The catalog from NINGBO HUASHENG MEDICAL EQUIPMENT CO.,LTD. shows oxygen flowmeters with humidifier bottles, an oxygen regulator assembly with a pressure gauge, and medical vacuum regulators with collection jars. Comparing these products by connection, readout and vessel design gives purchasing and technical teams a practical starting point for a quote.
Compare Oxygen Flowmeters by Fitting and Bottle Design
The pictured oxygen flowmeters have a clear upright measuring tube, a visible float and a ribbed side adjustment knob. Labels on two photographed configurations show a 1 to 10 L/min flow range. The transparent tube lets the user see the float against the scale, while the side knob keeps the adjustment point separate from the reading area. Buyers should use the range printed on the specific model label when preparing a product listing or request for quotation.
One configuration pairs a transparent teal humidifier bottle with a front-facing, green-collared tubing fitting and a side connection with a knurled collar. Another has a clear bottle with a broad green cap, a tubing fitting projecting from the cap and a differently shaped side connector. Both bottle designs show an internal stem with a light-colored tip. The transparent vessels make it possible to see the water level, and the location of the tubing fitting gives buyers a useful way to distinguish the assemblies in a distributor catalog. Confirm the inlet profile and bottle configuration together so that the quoted item matches the sample being reviewed.
Distinguish the Pressure Gauge from the Flow Scale
A separate oxygen assembly combines a flow tube and humidifier bottle with a regulator body, a hexagonal connection fitting and a round pressure gauge. The gauge face is marked from 0 to 25 MPa. This is the scale on the pictured dial, not a statement of allowable inlet pressure. The gauge and the flow tube are separate readouts: the first displays pressure, and the second indicates flow. For a cylinder-related sourcing inquiry, provide the required valve connection and ask for the model-specific operating specifications before judging suitability. Keep this configuration separate from outlet-style flowmeters on quote sheets and purchase orders.
Select a Suction Jar by Capacity and Closure
The vacuum assemblies show round analog gauges marked in MPa, controls labeled VAC and transparent collection jars. The 500 mL jar has an orange lid held by two side clips, with a tubing nozzle above the lid and visible graduations from 100 to 500 mL. The 200 mL jar has a white ribbed lid with a side nozzle and graduations from 50 to 200 mL. On these two models, the transparent jar wall and printed scale provide a direct view of the collected level. The capacity and closure differences are also useful identifiers when reviewing product samples or requesting replacement components.
A third pictured vacuum configuration has a rounded white regulator housing, a large front control and a clear jar below a ribbed white cap. Some pictured gauge faces use colored bands, while another uses a scale without those bands. These are visible design differences, not evidence that the assemblies share the same operating limits or that the jars and lids are interchangeable. Request the exact regulator and jar pairing in writing, especially when a tender specifies jar capacity or an existing installation requires a particular fitting.
Use the Catalog for Projects, Replacements and Stock Planning
Based in Cixi, Zhejiang Province, China, Huasheng presents several configurations across oxygen flow control, humidification and vacuum collection. For a hospital or clinic project, use the outlet schedule and equipment requirements to identify which pictured assemblies warrant technical review. For a replacement purchase, share the existing model label and a clear photo of the mating fitting so the inquiry starts with the installed equipment. For distributor stock planning, list the connection type, displayed range and vessel configuration as separate fields. That makes it easier for sales teams to distinguish models that look similar in a thumbnail but serve different orders.
In cross-border procurement, a familiar product name or color is not enough to establish fit. Buyers can reduce rework by asking for the specific model identifier, connector dimensions, included components and instructions for use before approving a quotation. Where local requirements apply, request the relevant documentation for the destination market. If a sample is evaluated, record the approved configuration against the purchase order so receiving teams have a clear reference for checking the shipment.
Request a Quote for Your Required Configuration
Contact NINGBO HUASHENG MEDICAL EQUIPMENT CO.,LTD. with the catalog image or model of interest, the required connection, your destination market and the expected order quantity. For oxygen equipment, specify the desired flow range and whether the inquiry is for a flowmeter with a humidifier bottle or a pressure-gauge regulator assembly. For vacuum equipment, include the required jar capacity and any lid or fitting requirements. Ask for a model-specific quotation and confirmation of the components included in each assembly.
Email: 113070564@qq.com Phone: 18606861888
About Author
You may also like
-
How to Choose the Right Torque for Automotive Fastening Tools
-
How BSJ Series Boss Roots Vacuum Pumps Improve Vacuum System Performance
-
Common Causes of Poor Airflow in Industrial Exhaust Systems and How to Address Them
-
China Private Label Heat Pump Solutions For Home Use In 2026
-
KDT: Driving the Future of Intelligent Woodworking Manufacturing